Adsorber (AD)
Venjakob's adsorption technology is particularly applied in the treatment of exhaust air from VOC of low and very low concentration. Adsorber (AD) is also used to smooth out pollutant concentration peaks. The adsorption process is based on the adhesion of VOC to a surface of AD resulting in VOC concentration increase. Then hot-tempered air of considerably lower flow-rate desorbs the pollutants from AD surface and streams to RTO, TI or CTO of compact size, where autothermal process can be rapidly achieved due to the high concentration of VOC. The excess of heat can be effectively utilized by application of heat exchanger system.
Exhaust air flow | 42.500 Nm3/h |
Pollutant type, VOC | Xylene, Isobutanol |
Pollutant heating value | 36.000 kJ/kg |
Pollutant concentration before AD | 200 mg/Nm3 |
Pollutant concentration after AD | 3.500 mg/Nm3 |
Hot air flow (desorption) | 2800 Nm³/h |
Exhaust air temperature before AD | 20 °C |
Exhaust air temperature after AD | 45 °C |
Electrical connection | 380-410 V / 50 Hz / 3 Ph +N |
Electric power requirement exhaust air fan | 6,5 kW |
Total installed power consumption | 11 kW |
Length x Width x Height approx. [m] | 2,4 x 2,9 x 3,1 |
Weight approx. | 0,4 t |
*data based on the AD 42.0, paint industry |
References
Ichtershausen
Kassel
Trnava
Weilmünster
Diepenbeek
Dresden
Lüdenscheid
Leipzig
Hamburg
Judenbach
Graben-Neudorf
Eching